UP↑SCALE › LABS, QUALITY & METROLOGY › LABORATORIES & PHARMACIES › COMPOUNDING ASSISTANT
Compounding on your balance: the formula step by step, the batch record as you go
A pharmacy preparation or a lab mixture has to be weighed right, from the right containers, and every step has to be on record. The compounding assistant of UP↑SCALE leads every batch from the approved master formula to the signed batch record: every component within its tolerance, every container checked, every lot and every deviation written down while you work - on the balance you already have.
- Master formulas approved by a QM, goals from the batch size
- Lots and use-by dates checked, every container scanned or confirmed
- Weighing within the tolerance of every ingredient, uniformity of mass
- A batch record sealed by the scale and signed by two people
In short
UP↑SCALE is one scale app for the balance you already have. Its compounding assistant leads every batch of a pharmacy or lab from the approved master formula to the signed batch record: lots and containers checked, every component weighed within its tolerance, filling with the uniformity of mass, a record sealed by the scale. For pharmacies and labs; it is part of ENTERPRISE & COMPLIANCE (from 13.00 EUR a month, 14 days free to try).
How a batch runs ENTERPRISE
- A QM approves the master formula once: ingredients in %, a tolerance per ingredient, SOP, shelf life and the steps in their order.
- You type the batch size - every goal in grams is worked out at once - and scan or type the lot and use-by date of every raw material. An expired or blocked lot stops the start.
- The balance leads you step by step: container check, weighing to the traffic light, instructions, checks, in-process controls, filling.
- ✔ FINISH: the batch record is ready - sealed by the scale, signed by the operator and reviewed by a QM - with the product label.
Choose ⚕ COMPOUNDING ASSISTANT in the menu (☰ → ⚖ MODES). It is a mode of the ENTERPRISE & COMPLIANCE edition - 14 days free to try on your scale.
Every step of a preparation
1Master formulas, approved by a QM ENTERPRISE
A formula holds its name and ID, the standard batch size, the dosage form, the shelf life in days, storage, the SOP, process parameters (stirring time 10 min, 40 °C) and up to 16 ingredients - each with its share in %, its own tolerance in % and an article number. Add the steps in their order: ⚖ weighing, 📋 instructions, ☑ checks (yes / no), 🔬 in-process controls with target ± tolerance (pH 5.5 ± 0.3) and 🫙 filling, plus a checklist for the start ("workplace cleaned?").
💾 SAVE keeps the formula on the scale with its whole process plan. With users, a saved formula is not approved until a QM approves this version - and a change of anything (rows, SOP, steps) needs a new approval. With the protection "only approved recipes can run", the scale opens no other formula.
Manual: master formulas, users and roles
2Batch size in, goals out - lots and use-by dates checked ENTERPRISE
Type the amount you want (500 g) and the scale calculates every goal from the %. Type the batch number or 🧾 GENERATE the next one from the lot generator of the scale. For every raw material: its lot (📷 scanned or typed - the lots you know are suggested) and its use-by date. Tick the checklist, then ▶ START BATCH.
The UP↑SCALE checks everything again by itself - use-by dates against its own clock, the lots of the lot store, the approval - and says what blocks the start: an expired lot, or a lot that is blocked or recalled, stops the batch. A tolerance narrower than one digit of the scale at this batch size is flagged and asked once more at the start; the batch record names the band that was accepted.
Manual: preparation, lot use-by dates, lot generator
3Weighing step by step, within the tolerance ENTERPRISE
The scale tares at the start of the step and shows the live weight against the goal: yellow = add more (it says how much), green = within the tolerance of the ingredient, red = too much. ⚖ OVERTAKE works when the weight is stable: green - the value is taken with who and when, and the next step comes; yellow - the amount stays in the container as a part and counts. You are not tied to the order: tap any ingredient to weigh it now, and add more to one later - every part and every addition goes into the record.
Too much? Take some out - or a user with the role QM (never the user logged in on this device) gives a 🔏 QM RELEASE on the spot with password and reason; the scale checks the password and writes the release into its activity log. Or 🧮 calculates the other goals again in the proportion of this one (noted in the record).
The balance runs the batch, not the phone: only the ingredient of the current step can be weighed, and every connected device shows the same batch. A reload, another phone or a power loss loses nothing - open the formula again and the batch goes on where it was.
Manual: the guided steps, stability light, minimum weight
4The right container: confirm the label or scan it ENTERPRISE
With the identity check in the formula, a weighing step stays locked until its container is checked. The approved codes (GTIN / EAN / article number), label names and grade are kept in the THING of the ingredient - the same for every lot. Scan the code with the camera or a hand scanner, or ✋ CHECK THE LABEL: the window lists the approved label names, the grade and the lot of the batch, and you confirm it.
A code that is not approved, a GS1 code with another lot than the one of the batch, or one with a use-by date in the past gives ⛔ wrong container - the step stays locked. Every check (scanned or confirmed) and every wrong scan goes into the batch record. If the codes or names of a THING change later, the formula has to be saved (and approved) again before it starts.
Manual: identity check, identity data of a THING
5Instructions, checks and in-process controls ENTERPRISE
📋 Instructions are confirmed with ✔ DONE, ☑ checks with ✔ YES - a ✕ NO asks why and goes into the batch record as a deviation. For a 🔬 in-process control type the measured value (pH, temperature ...): the UP↑SCALE judges it against target ± tolerance, and outside it asks for the reason. With a room sensor connected, an IPC step in °C, %RH or hPa can take the value of the sensor.
Manual: the guided steps, sensors
6Filling with the uniformity of mass ENTERPRISE
The filling step weighs every container: tare the empty one, fill it, ✔ TAKE - with AUTO TARE you only swap containers. The scale keeps every unit and shows the verdict, mean, standard deviation, min / max, the units outside the limit and outside twice the limit, a run chart and from 10 units a histogram.
Along Ph. Eur. 2.9.5 for capsules, single-dose granules and powders, tablets, suppositories and pessaries: 20 units, not more than 2 may deviate from the average by more than the limit of the table, none by more than twice the limit. Or your own limit in ± % around the target fill (jars of a cream): every unit must be inside. Not met? The app asks why the batch may go on - a deviation in the record. The maths is checked by the public validation cases UM-01 to UM-07 on the check page.
Manual: filling and uniformity of mass
What stays on record
The activity log of the scale with user and time - and the check page, where anybody can see that a sealed file is unchanged.


More about the app, with all screenshots →Screenshots of the real app with demo values - a screenshot may show the look of an older app version.
The batch record, signed by two people ENTERPRISE
✔ FINISH ends the batch on the scale, books every ingredient into the weighing log with its own lot and the person who weighed it, and takes the raw materials out of the stock. The batch record holds:
- formula, ID and approval (fingerprint), batch number, start and end, operator, batch size, use-by date of the product, the scale and its calibration
- every ingredient with article number, lot, use-by date, goal, weighed amount, deviation in %, tolerance, who and when - and who released a value and why
- the checklist with times and names, every step with its result (in-process values, checks), the single fills with the uniformity of mass, all deviations and recalculations, the SOP
- with a room sensor: air temperature, humidity and air pressure at the start and the end of the batch, with the sensor
- on a verified RS-232 balance: the alibi number of the balance below every ingredient and every fill (EXTRA LINE, or ALIBI ON TAKE presses the print key for you)
⎙ PRINT, 📄 PDF (SEALED) or ⇩ HTML with your company header, the report number and the integrity code. The PDF is sealed by the scale and carries the record as a JSON file. The operator ✍ SIGNS it (performed), later a QM signs it as reviewed / approved - the scale refuses a QM who made the report (four eyes). Anybody can check the file on the check page. 🏷 LABEL prints the product label: name, batch number with a QR code, dosage form, quantity, made on, use by, the ingredients, storage and a free text.
Manual: batch record, scale seal, alibi on take, label printers
Records and audit trail
- 🗂 RECORDS → BATCHES keeps every batch record in this browser: print it again, make the sealed PDF, sign it, the label, and a CSV of all batches.
- The activity log of the scale holds the start and end of the batch, every QM release, every signature and every seal - hash-chained, with user and time. The audit trail in detail →
- To your LIMS or ELN by itself: with the forwarding of finished programs every batch record goes to your server at the end - as JSON, and if you want also as the file sealed by the scale. LIMS & ELN forwarding →
- For your validation file: the validation pack has a chapter of its own for the compounding assistant. Introducing it in a regulated lab →
Tamper-evident, not unchangeable: the seal and the hash chain show a change, but the browser is no archive. Keep the PDF files on your own read-only, backed-up storage.
Manual: forwarding of finished programs, tamper-evidence, validation pack
Checklist before your first batch
- Set up users with roles: at least one operator and one QM with a password (the four-eyes steps need both)
- Save every ingredient as a THING - with its approved codes and label names if you use the container check
- Enter your formulas, have them approved by a QM, and switch on "only approved recipes can run"
- Keep the lots of your raw materials in the lot store with their use-by dates
- Do the daily balance check and type in the minimum weight of your balance
- Decide where the sealed PDF files are kept, and who signs as QM
The limits - honestly
- Not a medical device and no official approval: it is a weighing and record tool. The pharmacist in charge and your QA decide whether a preparation may be made and released, and whether the assistant fits your SOP.
- A record that people sign, never a certificate: the batch record is made for the records pharmacy and GMP work asks for, but it makes no claim of compliance. The signatures are no qualified electronic signatures.
- Verified balances in Germany: the weighings must be traceable to the alibi memory of the balance (EXTRA LINE) or to certified software - see pharmacies with a verified balance.
- One batch at a time per UP↑SCALE, up to 16 ingredients per formula.
- ENTERPRISE & COMPLIANCE only - gray in FREE and PRO, not on the free virtual scale.
- The browser is no archive: 🗂 BATCHES lives in this browser - keep the sealed files on your own storage.
For laboratories & pharmacies → · all lab and quality functions →
The compounding assistant: questions and answers
Is there pharmacy compounding software that runs on the balance?
Yes: the compounding assistant of UP↑SCALE ENTERPRISE & COMPLIANCE. The scale holds the master formula and the running batch, leads every weighing to the traffic light, checks the containers and lots, and writes the batch record - on an UP↑SCALE scale or on the lab balance you already have with the RS-232 adapter.
How are the goals of a batch calculated?
The formula keeps every ingredient as a share in %. Type the batch size (e.g. 500 g) and the scale works out every goal in grams. Weighed too much of one? 🧮 calculates the other goals again in the proportion of this one, noted in the batch record.
What happens with an expired lot?
The batch does not start. The UP↑SCALE checks the use-by date of every raw material against its own clock, and a lot that is blocked or recalled in the lot store stops the start too.
How does the container check work?
The approved codes, label names and grade of every ingredient are kept in its THING. Before a weighing step, scan the code of the container or confirm its label. A code that is not approved, another lot or a use-by date in the past keeps the step locked - and every check goes into the batch record.
Does it check the uniformity of mass?
Yes. The filling step weighs every unit and judges it along Ph. Eur. 2.9.5 (20 units, the limits of the table around the average) or against your own limit in % around the target fill. The maths is checked by public validation cases on the check page.
Who signs the batch record?
The operator signs it as performed, a QM signs it as reviewed or approved. The scale checks the password every time and refuses a QM who made the report - four eyes. Every signature is an entry in the activity log of the scale.
Is the batch record a certificate?
No. It is a record that people sign, sealed by the scale so that a change shows. Whether it fits your SOP is decided by your QA and the pharmacist in charge; the app is no medical device and has no official approval.
Can the batch records go to our LIMS?
Yes, with the LIMS / ELN forwarding of finished programs (ENTERPRISE): every batch record goes to your own server at the end as JSON, and if you want also as the file sealed by the scale.
Also useful for you
21 CFR Part 11 audit trail
Labs, quality & metrologyWho, when, what and why in the scale - mapped to Part 11, EU GMP Annex 11 and ALCOA+, point by point, with the limits.
Read →Daily balance check (USP <41>)
Labs, quality & metrologyUSP <41> repeatability and minimum weight, Ph. Eur. 2.1.7, trade and HACCP checks in one minute a day.
Read →QA guide: validation (IQ/OQ/PQ)
Labs, quality & metrologyIntroducing it in a regulated lab: the QA tasks, what the app takes over, IQ / OQ / PQ, an estimate of the effort and the steps to the sign-off.
Read →LIMS, ELN & sensors
Labs, quality & metrologyEvery weighing to your LIMS or ELN, room values next to it, air buoyancy corrected.
Read →USP <41> minimum weight
Repeatability, minimum weight (2000 s) and accuracy of your balance from your weighings.
Read →Who else uses it
Lab & pharmacy: more pages
The same app, for other work
Every function is in the same app - at home, in business and in the lab. All functions at a glance.