Laboratory balances with records you can prove
A laboratory has to show that its balances are fit for use, that its records are complete and unchanged, and who did what. UP↑SCALE adds the routine check, the test suite, pipette checks and calibrations and a tamper-evident audit trail to the balance you already have - for work under ISO/IEC 17025, GLP/GMP and 21 CFR Part 11.
- Compounding assistant from formula to batch record
- Pipette checks and calibrations along ISO 8655-6
- Routine check along USP <41> / Ph. Eur. 2.1.7
- Tamper-evident audit trail and sealed PDF reports
In detail: Pipette calibration · Daily balance check (USP <41>) · Compounding assistant · LIMS, ELN & sensors
In short
UP↑SCALE is one scale app for the lab balance you already have, on an RS-232 adapter. Labs and pharmacies get the compounding assistant, pipette checks and calibrations, routine checks before use, a test suite and records they can prove: users, roles, a hash-chained audit trail and sealed reports. The routine check is free; ENTERPRISE & COMPLIANCE costs 144.00 EUR a year or 599.00 EUR once per scale, the board about 13.50 EUR.
What helps you most
⚕ Compounding Assistant: from the master formula to the signed batch record ENTERPRISE
The balance guides every weighing of a preparation, checks every container and lot, and writes the batch record while you work - for pharmacy preparations, stock batches, creams, capsules and lab mixtures, on the balance you already have.
The QM approves the formula
Ingredients in %, tolerances, SOP, shelf life and in-process controls - four eyes before it can run.
The balance guides you
Type the batch size; scan every lot and container, weigh to the traffic light, OVERTAKE when green and stable.
The batch record is ready
Every lot, weight and deviation with who and when - a PDF sealed by the scale, signed and reviewed, plus the product label.
Before the start
- Master formulas kept by the scale: ingredients in %, a tolerance per ingredient, article numbers, SOP, shelf life, process parameters, checklists and in-process controls - approved by a QM before they can run.
- Lots: type the batch size (500 g) and every goal is calculated; scan the lot of every raw material with its use-by date - an expired or recalled lot blocks the start.
At every step
- The right container: scan it (GTIN, lot and use-by of a GS1 code are checked) or confirm its label - the approved codes, label names and grade are kept in the THING. A wrong container keeps the step locked; every check and every wrong scan is in the batch record.
- Guided weighing: the scale tares, a big goal and a traffic light (yellow - green - red), any ingredient in any order (a part in the container counts). Too much? A QM releases it on the spot with password and reason - the scale checks and logs it.
- In-process controls (pH 5.5 ± 0.3, temperature ...), instructions and checks with time and name - a value out of range asks for the reason.
- Filling with the uniformity of mass along Ph. Eur. 2.9.5 (20 capsules, suppositories, tablets ...) or your own limit for jars.
Nothing can be skipped
- The balance runs the batch, not the phone: the UP↑SCALE checks the start, the order of the steps and every container itself - a second device or a reload can not skip a step, and the batch goes on after a power loss.
The batch record
- Every ingredient with lot, use-by date, goal, actual weight, deviation, who and when; checklists, IPC values and deviations - as a PDF sealed by the scale, signed by the operator and reviewed by a QM. Plus the product label with batch number and use-by date.
A German pharmacy with a verified balance? You can use it today.
- The rule: every weighing must be traceable to software with a certificate of a conformity assessment body - or to the alibi memory of your balance. The compounding assistant takes the second way.
- How: with the EXTRA LINE the batch record shows the alibi number of the balance below every ingredient; with ALIBI ON TAKE the UP↑SCALE presses the print key of the balance itself at every OVERTAKE. The alibi memory of your balance stays the legal record.
- No alibi memory? 🔏 LEGAL MODE (ENTERPRISE) stores every value on the UP↑SCALE first, with the line of the balance and its own number. Its certificate for this use is planned for our 232 UP↑SCALER; until then, ask your verification office (Eichamt).
A record that people sign, never a certificate: whether it fits your SOP is decided by your QA.
Manual: compounding assistant, the batch record, lot use-by dates, what stays legal
The compounding assistant in detail →
💧 ⚗ Two lab modes for pipettes: the pipette check and the pipette calibration PROENTERPRISE
Your lab balance on an UP↑SCALE RS-232 adapter checks and calibrates the pipettes of every maker. The UP↑SCALE guides every step, takes every delivery from the balance by itself and does the maths - your hands stay on the pipette:
- 💧 Pipette check PRO: an intermediate check between calibrations (ISO/IEC 17025, 6.4.10) - one volume, a few deliveries, the systematic and the random error against the limits of the pipette, PASS or FAIL in a few minutes. No calibration and no uncertainty: it keeps confidence in a pipette until its next calibration. Also with the virtual scale and a balance on a USB cable.
- ⚗ Pipette calibration ENTERPRISE: a calibration along ISO 8655-6:2022 - nominal, 50 % and the lower volume, 10 deliveries each, every channel, the evaporation measured, the environment at the start and the end, as found and as left.
- The uncertainty of every volume along ISO/TR 20461:2023 with each contribution, the uncertainty in use with your operator, laboratory and process effects, your CMC table (the reported U is never below it) and the decision rule of your choice.
- The calibration report sealed by the scale, with your own title and accreditation text and the signatures of the tester and a reviewer; every calibration goes into the activity log.
- The pipette register: your own labels and ours side by side (QR, Code 128, Code 39, GS1), stickers and status tags on your label printer, the due dates with reminders and a calendar file, the makers' specifications of common pipettes built in (with the document), a history chained with SHA-256, customers for calibration services, the import of the pipette list of your old system with an import record - shared live between your devices.
- A balance that is fine enough: ISO 8655-6 asks for d 0.001 mg below 20 µL, 0.01 mg from 20 µL and 0.1 mg from 200 µL - the app shows it for every test volume. Every option has an ℹ️ that explains it.
- Dispensers and piston burettes too: bottle-top and repeating dispensers (ISO 8655-5) and piston burettes (ISO 8655-3, manual or a titrator's dosing unit) in the same register and the same modes - the vessel may leave the balance for a delivery, the limits and the report follow the instrument, and every title names it, so it is never mixed up with the calibration of your balance.
- Volumetric glassware too: flasks, measuring cylinders, one-mark and graduated glass pipettes and glass burettes, built along ISO 4787:2021 - to contain or to deliver, against the class A, AS or B tolerance of an ISO or ASTM / USP table, with the meniscus in the uncertainty. A receipt check is PRO, a calibration ENTERPRISE.
Traceable and accredited are yours: the traceability comes from your calibrated instruments, an accredited calibration from your ISO/IEC 17025 scope. The maths are part of the validation of the calculations.
The jobs in detail: Pipette Check & Calibration
Manual: pipette check, pipette calibration, uncertainty, CMC table, register
Pipette calibration along ISO 8655-6 and pipette checks in detail, with screenshots →
🇺🇸 For US labs: CLIA, CAP, FDA GLP / GMP and NIST-traceable pipette records PROENTERPRISE
The US has no pipette standard of its own any more: ASTM E1154 (piston-operated volumetric apparatus) was withdrawn in 2023, and US calibration labs and their accreditation bodies (A2LA, ANAB) work with ISO 8655 and ISO/IEC 17025 - the standards the pipette modes are built along. What the US rules ask for, and what you get:
- Clinical labs under CLIA (42 CFR Part 493) and CAP-accredited labs: pipettes checked for accuracy and precision at intervals you define, with records. The pipette check gives you the check in a few minutes, the due dates in the register, a sticker on the pipette and a run record with every single value.
- FDA GMP (21 CFR 211.160(b)(4), calibration of instruments at suitable intervals under a written program) and FDA GLP (21 CFR 58.63, equipment calibrated, records kept): the pipette calibration with as found / as left, the sealed calibration report and the history of every pipette.
- 21 CFR Part 11: users with roles, reasons for changes, the hash-chained audit trail and electronic signatures on the report (ENTERPRISE).
- NIST-traceable: the traceability to NIST and the SI comes from your calibrated balance, weights, thermometer, barometer and hygrometer - the report lists them with their certificates. The volume maths follow the gravimetric model of NIST SOP 14 (NIST IR 7383) and are checked against the published examples of EURAMET cg-19 in the validation of the calculations.
- The room: the report names every deviation from the ISO 8655-6 conditions (20 ± 3 °C, 45 - 80 %RH) instead of hiding it; a balance check along USP <41> is the routine check.
Records and controls - not a claim that you comply: whether an inspector or assessor accepts them depends on your own procedures.
Pipette check & calibration in detail →
Manual: pipette check, pipette calibration, for regulated laboratories
What your lab can save
Our estimate at 100 EUR per hour: about 12,000 EUR in the first year and 32,000 EUR in 5 years for one scale; a workplace with 5 scales about 50,000 EUR in the first year and 150,000 EUR in 5 years - validation hours and software subscriptions you do not need. See the table and enter your own hourly rate →
1Routine check before use - along USP <41> and Ph. Eur. 2.1.7 FREE+ ENTERPRISE
The short check before you work: put a known weight on a few times, the app takes every value by itself and says PASS or FAIL. Profiles for the pharmacopoeias: one weight 10 times, the repeatability as 2 × standard deviation / smallest net weight ≤ 0.10 % (a standard deviation below 0.41 d counts as 0.41 d), accuracy (USP, 0.10 %) or sensitivity (Ph. Eur., 0.05 %) with a weight of at least 5 % of Max - and the minimum weight of your balance (2000 × s). Or your own SOP with your own limits and number of weighings.
A failed check shows a warning until a re-test passes; removing it needs an ADMIN and a reason. The scale itself keeps the interval and the last result, so every device knows when the next check is due. With ENTERPRISE the whole log becomes a sealed PDF report.
Minimum weight warning ENTERPRISE: type in the minimum weight from the calibration certificate of your balance once - it is kept by the scale. A sample below it (2 mg on a balance with a minimum weight of 10 mg) asks before it is recorded, as a sum, a sale or a label; recorded anyway, the activity log notes it with the weight.
Air buoyancy correction ENTERPRISE: a balance shows the conventional mass (adjusted with steel weights). For a THING with a known density the app shows the true mass next to the reading - water +0.105 %, ethanol +0.137 % - in the weighing, the solution mode and recipes (the goals are true masses, the scale judges green/red with the correction), the density mode (with the air term), the weighing log, the reports and the LIMS events. The air density is 0.0012 g/cm³ or typed in, or worked out from temperature, pressure and humidity (OIML R 111) - typed or from a room sensor, kept up to date when you switch it on; it is kept by the scale for every app, and every change is logged. The reading itself is never changed.
📡 Room and water from sensors PRO: a room sensor (air temperature, humidity, air pressure) and a thermometer of another maker - Bluetooth, broadcast or USB cable, a transmitter on RS-485 (Modbus RTU, e.g. Vaisala HMP110) or the monitoring system you already have (HTTP JSON, MQTT) - fill the conditions of the pipette runs, the air buoyancy correction, the density mode and the tests, and the batch and solution records keep the room at the start and the end; a typed value always wins. With ENTERPRISE the register keeps the certificates, due dates, U and corrections of your sensors and instruments and names them with every value, and the room log keeps one value a minute with limits and warnings while the app is open - and forwards it, with every limit crossing, to your LIMS or a webhook. A sensor that stops sending is noted, and no old value ends up in a record (all ways to connect a sensor).
Stability light ENTERPRISE: STABLE is not always settled - draft or vibration can still move the weight inside one digit. The scale watches how much the weight still moves and the app shows MOVING, SETTLING (pulsing) and SETTLED. Labels and records wait for SETTLED and save by themselves then, with a short beep - or you save anyway.
Solution mode PRO: standard and stock solutions in fixed proportions. Weighed 10.4 mg instead of 10.0 mg? 🧮 calculates the solvent again (52 ml instead of 50 ml) - the concentration stays the same. Every connected device shows the same rows; saved with a short SOP. With ENTERPRISE the solution report with seal and electronic signature.
The jobs in detail: Laboratory Scale
Manual: routine check, minimum weight, air buoyancy, sensors, stability light, solution mode
The daily balance check (USP <41>) in detail → · Room sensors, air buoyancy and LIMS in detail →
2Users, roles and a reason for every change ENTERPRISE
Up to 50 users with login and password, kept in the scale - the same for every connected computer. Roles: user, operator (may weigh, may change nothing), QM / approver and ADMIN. With strict audit the scale refuses every change without a reason. Everything relevant that goes over Bluetooth is encrypted by current standards (AES-128, ECDH P-256 key agreement), so nothing can be sniffed over the air; passwords are additionally sealed in an envelope that only the scale can open.
3A tamper-evident audit trail ENTERPRISE
The scale writes an activity log of the last 10,000 events: who weighed, changed, approved or deleted what, when and why - calibration, density and the settings that change the weight with the old and the new value. Every entry has a running number and is linked to the one before by a SHA-256 hash chain. The app archives the log while it is connected and saves it as record files that are linked by hash too, with a matching printout. A changed, removed or missing entry shows up when it is checked. With strict audit the log is no rolling buffer (FIFO): before an entry that no app has archived would be overwritten, the scale stops new sales, programs and changes until the app has archived the log - connect the app and work goes on, no entry is lost. (Without strict audit the oldest unarchived entries are overwritten, but never silently: the lost numbers are recorded and shown.)
The jobs in detail: Audit Trail & Sealed Records
Manual: how it works, all logs
Part 11, Annex 11, ALCOA+ point by point →
4Numbered reports, sealed by the balance ENTERPRISE
Every printed or saved report gets a running number counted by the scale and an integrity code. The scale seals it: it signs the SHA-256 of the report with its own key (ECDSA P-256) and writes the seal into its activity log. PDF reports, record files and exports are sealed the same way - and anybody can check a sealed file on up-scales.com/check, in the browser, nothing is uploaded.
Manual: the UP↑SCALE SEAL, sealed or signed?
5Four eyes: recipe approval and signatures ENTERPRISE
A recipe (a weighing procedure) saved by one person must be approved by a QM who did not save it - and with the gate on, only approved recipes can run. Reports get electronic signatures with their meaning (performed, reviewed, approved); the scale checks the password at every signature and logs it.
These are not qualified electronic signatures (no certificate of a trust service).
6The test suite, scale calibration and certificates FREEPROENTERPRISE
Repeatability, eccentricity, accuracy and linearity, creep, warm-up and more - along OIML R 76-1 Annex A and EURAMET cg-18, with a checklist per procedure. The equipment register keeps the test interval and the due date, the test history stays on the scale with a trend chart. The simple tests are free, the extended tests PRO. With ENTERPRISE: the register and reports, the scale calibration along EURAMET cg-18 with the uncertainty of every load and in use, and calibration certificates of your lab for scales and pipettes - standard, or with your own accreditation, its symbol and CMC - with a completeness check against the listed rules, procedures, signatories and a certificate register with amendments.
The jobs in detail: Scale Test Suite
Manual: scale calibration, certificates
Every scale test (eccentricity, linearity, repeatability) in detail →
7Validation pack (IQ / OQ / PQ) and the validation of the calculations ENTERPRISE
The app carries reference cases worked out by hand from OIML R 76-1 - and for the pipettes from ISO 8655-6, the water density of Tanaka and the air density of OIML R 111 - and runs them against its own code - with a fingerprint of the code and the cases. The result is an IQ/OQ record for your own validation file. The same run can be exported as raw data (CSV / JSON, sealed) or sent to your LIMS, ready for your quality management system. The cases are public on the check page.
The validation pack puts it all into one document for your validation file: plan and scope, the system as it is (versions, fingerprints, balance, instruments, settings), the references with their editions, the requirements with their tests, a risk assessment to confirm, the IQ, the OQ with the reference cases of your device and test scripts for your tester (weighing data path, audit trail, roles, lockout, signatures, seal, export, time, power cut - and for the pipettes from a delivery with a calibrated weight to the CMC), chapters of their own for the compounding assistant, the routine check, the fill weighing, the density mode and the LIMS forwarding - tick only what you use - the PQ, a 21 CFR Part 11 / Annex 11 checklist, change control and the pages to sign. Your laboratory executes and approves it; the pack brings the structure and the data.
Route for final sign-off: one button binds the signed IQ/OQ record, the PQ baseline report of the test suite and a hardware inventory made at that moment into a Validation Summary Report (VSR) - a sealed PDF with lines to sign, or signed in the app. Once a QM signs it approved (four eyes, password checked by the scale), the scale is released for use; every device shows it, and a later calibration, configuration change or new firmware asks for a new release.
See it before you buy: our sample validation pack (sealed PDF, 42 pages) - or read it in the browser. Made on a test unit with demo values: every chapter, demo instruments and three demo pipettes, the 304 reference cases of its firmware in annex A. It shows what the app fills in and judges itself (versions, fingerprints, edition, balance, users and roles, the instruments and the balance for every pipette) and what it leaves for your tester. Drop the PDF on the check page: the seal is valid, with the certificate of the scale.
Manual: validation pack, validation, VSR and release
8And for the bench work FREE
Weigh solvents and chemicals directly in ml (hundreds of densities built in), measure the density of solids, follow evaporation or drying over hours with the tracking mode, and use fine balances down to 0.1 µg steps with every digit (EXACT WEIGHT).
Standard and stock solutions? The solution mode weighs the ingredients in grams, percent or parts and calculates the rest again if you put too much of one in.
Several small objects to weigh as exactly as your balance allows? Weigh them alone and together (A, B, A+B …): the combination weighing of the statistics fits every mass to all weighings by least squares and shows its standard uncertainty.
A restless table? The environment filter (AUTO) tests the place from time to time while the scale stands still and adapts the averaging by itself - your saved settings stay as they are. On our load-cell scales the creep compensation corrects the slow creep of the load cell at every weight, measured once with the creep test.
The jobs in detail: Laboratory Scale, Standard Solution Scale, Density Scale, Drying & Tracking Scale, Multi-Interval Scale, Statistics Station
Manual: combination weighing, environment filter, creep compensation
Complete on the product side
Everything an audit can expect from a balance and its software is built in. These are the technical controls:
- Audit trail in the scale: who, when, what and why, with the old and the new value, hash-chained, for every connected device (21 CFR Part 11 §11.10(e), Annex 11 §9).
- Access: users with permanent numbers and roles, lockout after wrong passwords, password age, and QM-signed reviews of the access and of the audit trail (§11.10(d), (g), §11.300, Annex 11 §12).
- Electronic signatures: name, date and meaning, checked by the scale and linked to the record (§11.50, §11.70).
- Sealed records: reports, PDFs, record files and exports, which anybody can check on up-scales.com/check (§11.10(b), (c)).
- Time and storage: the device qualification for the clock and the WORM storage, plus the clock guard of the scale with the signed exact time from up-scales.com as its reference.
- Tests and maths: the test suite along OIML R 76-1, the routine check, and the validation of the calculations (IQ/OQ record).
What stays with you is what no product can do for you: your validation, your SOPs, training, checking who your users are, and the storage and time servers that your IT runs. The app brings the forms and templates for these too.
How it saves time:
- For QA: the documents for the binder come out of the app, filled in by the app, sealed and with signature lines: device records, the user access register, the device register, test records, routine check logs, review records and the IQ/OQ record. You need no consultant for the paperwork, no extra validation package and no subscription.
- For the auditor: checking a file takes a minute on the public check page, without an account or an upload. The reviews, the signatures and the log entry of every seal are in the records, so an auditor asks for a certain entry instead of leafing through paper logbooks.
Built to the expectations of 21 CFR Part 11, EU GMP Annex 11, ISO/IEC 17025, GLP and ALCOA+. No software is compliant by itself: compliance comes from your validated system together with your procedures. This is not a certification.
21 CFR Part 11 audit trail in detail → Device qualification: time sync & WORM storage → The routine check → The test suite → Pipette check & calibration → The compounding assistant → LIMS, room sensors & air buoyancy →
Tips from the practice
- Validate your setup: no software is "compliant" by itself - compliance comes from the validated system together with your SOPs. The manual lists exactly what each control does, so you can judge it.
- Qualify every device once: the scale has no clock and a disk is not write-once - the built-in device qualification gives your IT the templates (time server locked, records straight to WORM storage), fills in the form by itself and makes the sealed record for your binder, signed electronically; the scale keeps the device register and logs every clock jump - against the exact time signed by up-scales.com, if you set it with one click.
- Keep the fingerprint of the newest record file apart from the files (binder or QA system).
- Password rules and reviews: switch on a maximum password age, and let a QM sign the access review and the audit trail review at your interval - both are kept by the scale (password rules, audit trail review).
- One user per person: the user access register ties every user number to a real name, role, authorization and training, with the review date - print it as a signed PDF for your binder.
- Every user needs a password for strict audit - set it before you switch it on.
- Straight into your LIMS or ELN: the app can forward the live weight and tracking alarms (PRO) and the activity log, sales, weighings, sealed reports, the release state of the scale (routine check, minimum weight) and the room log of the sensors (ENTERPRISE) as JSON to a server in your own network or a webhook (n8n, Node-RED ...) - no third-party cloud. It sends while the app is open and connected; the activity log catches up by itself at the next connection (LIMS / ELN forwarding, in detail).
Checks, statistics and sealed records in the app
The routine check before use along USP <41>, statistics of your series - and reports the scale seals itself, which anybody can check.



More about the app, with all screenshots →Screenshots of the real app with demo values - a screenshot may show the look of an older app version.
Pipettes in the app
Set up the calibration of a pipette, dispense - the UP↑SCALE takes every value by itself - and get the result of every volume with its uncertainty and your CMC.



More about the app, with all screenshots →Screenshots of the real app with demo values - a screenshot may show the look of an older app version.
The rules you should know
- 21 CFR Part 11 (FDA) and EU GMP Annex 11: electronic records and signatures, audit trail, access control
- ISO/IEC 17025 and GLP / GMP: equipment fit for use, records complete and traceable (ALCOA+)
- USP <41> / <1251> and Ph. Eur. 2.1.7: balances for analytical work - repeatability, accuracy, minimum weight
- ISO 8655-2 / -6:2022 and ISO/TR 20461:2023: the limits of piston pipettes, their gravimetric calibration and its uncertainty; ILAC P14 and ILAC G8: the CMC on reports and the decision rules
- In the US: CLIA (42 CFR 493) and the CAP checklists, 21 CFR 211.160 (GMP) and 21 CFR 58.63 (GLP): instruments calibrated and checked at defined intervals, with records; pipettes along ISO 8655 since ASTM E1154 was withdrawn (2023); NIST SOP 14: the gravimetric volume model
UP↑SCALE gives you technical controls and records - it makes no claim that you comply with a rule or that an auditor accepts them. Tamper-evident, not write-once: the memory of the scale and files on a disk can still be overwritten or deleted, but that does not go unnoticed. Details and limits: for regulated laboratories, tamper-evident records.
Lab balances and audit trail: questions and answers
Can a German pharmacy use the compounding assistant with its verified balance?
Yes, today - with a balance that has an alibi memory: switch on the EXTRA LINE and ALIBI ON TAKE (the UP↑SCALE presses the print key of the balance at every take - or you press it yourself), and the batch record shows its alibi number below every ingredient. The alibi memory of the balance stays the legal record and every value of the batch record is traced to it - that is what the rules for pharmacy records ask for (software with a certificate, or an alibi memory with every value traced to it). A balance without an alibi memory: 🔏 LEGAL MODE stores every value on the UP↑SCALE with its own number; its certificate for this use is planned for our 232 UP↑SCALER - until then, ask your verification office.
Can I add a 21 CFR Part 11 audit trail to the lab balance I already have?
Yes, the technical controls. Plug the RS-232 adapter into your balance and use the ENTERPRISE & COMPLIANCE edition: users with roles and passwords, a hash-chained audit trail in the scale with the old and new value and the reason, electronic signatures and sealed reports. No software is compliant by itself - compliance comes from your validated system and your SOPs. Part 11 point by point.
How do I do the USP <41> balance check?
Choose the USP <41> profile of the routine check: one weight 10 times for the repeatability (2 × standard deviation / smallest net weight ≤ 0.10 %, a standard deviation below 0.41 d counts as 0.41 d) and a weight of at least 5 % of Max for the accuracy (≤ 0.10 %). The app takes every value by itself and says PASS or FAIL. The routine check in detail.
How do I find the minimum weight of my balance?
The lab profiles of the routine check show it: 2000 × the standard deviation of the repeatability. With ENTERPRISE you type in the minimum weight from the calibration certificate once, and every sample below it asks before it is recorded.
Is there a compounding software that runs on the balance?
Yes: the compounding assistant (ENTERPRISE). Master formulas approved by a QM, the lot and use-by date of every raw material, an identity check of every container, guided weighing with a traffic light, in-process controls, the uniformity of mass along Ph. Eur. 2.9.5 and a batch record sealed by the scale and signed by operator and QM. A record that people sign - never a certificate.
Can we check and calibrate our pipettes on our own lab balance?
Yes, with the RS-232 adapter on a balance that is fine enough for the volumes. The pipette check (PRO) is an intermediate check between calibrations: one volume, a few deliveries, PASS or FAIL. The pipette calibration (ENTERPRISE) runs along ISO 8655-6:2022 with the uncertainty of every volume, your CMC table and a sealed calibration report. The UP↑SCALE takes every value from the balance by itself. Pipette check and calibration in detail.
Is there a US standard for pipette calibration, like ASTM E1154?
ASTM E1154 (piston or plunger operated volumetric apparatus) was withdrawn in 2023. US calibration labs and the accreditation bodies A2LA and ANAB work with ISO 8655 (limits and the gravimetric procedure) and ISO/IEC 17025 - the pipette check and the pipette calibration of UP↑SCALE are built along ISO 8655-6:2022.
Does the pipette check help with CLIA and CAP pipette requirements?
CLIA and the CAP checklists ask for pipettes checked at intervals the lab defines, with records. The pipette check gives you the check (systematic and random error, PASS or FAIL), the due dates, a sticker and a run record with every value; the pipette calibration adds the sealed report with the uncertainty. Whether an inspector accepts your records depends on your own procedures - UP↑SCALE makes no claim of compliance.
Is the pipette calibration NIST traceable?
The traceability to NIST and the SI comes from your calibrated balance and weights, thermometer, barometer and hygrometer: enter them with their certificates and the calibration report lists them. The volume calculation is the gravimetric model of NIST SOP 14 and is checked against the published examples of EURAMET cg-19.
Can we take over the pipette list of our old calibration software?
Yes: export it as CSV or JSON, check the column mapping and the preview, and import it. The last calibration and the due dates come along, your own labels keep working, and the import record with the SHA-256 of the file documents the transfer.
Do I need a PC at the balance?
No. The app runs on a phone, tablet or any computer with a browser, and the data go only over Bluetooth between scale and device - never over the internet, also with the online app. No balance PC, no software to install, no server.
Can the balance send its results to our LIMS or ELN?
Yes. The app forwards events as JSON to a server in your own network: the live weight and tracking alarms with PRO, the activity log, sales, weighings, sealed reports, the release state of the scale and the room log of the sensors with ENTERPRISE. It sends while the app is open and connected; no third-party cloud.
Can it use the room sensors and thermometers we already have?
Very likely: Bluetooth sensors (RuuviTag, Aranet4, ETI BlueTherm and every device with the standard Environmental Sensing or Health Thermometer service), sensors on a USB or RS-232 cable, transmitters on RS-485 with Modbus RTU, and your monitoring system over an HTTP JSON address or MQTT. Instruments without a connection - a calibrated glass thermometer, a hand-held barometer - go into the register too and are named with the values typed from them.
Does it correct for air buoyancy?
Yes, with ENTERPRISE: for a substance with a known density the app shows the true mass next to the reading (water +0.105 %, ethanol +0.137 %), with the air density of 0.0012 g/cm³, typed in, or worked out from temperature, pressure and humidity (OIML R 111). The reading itself is never changed.
Is the software validated?
The app brings the validation of its calculations: reference cases worked out by hand from OIML R 76-1 run against its own code and make an IQ/OQ record with a fingerprint of the code. The validation of your system stays yours, but you do not start from an empty page: the validation pack is one document with plan, references, requirements, risk assessment, IQ, OQ test scripts, PQ and a Part 11 / Annex 11 checklist, filled in with the data of your system - your tester executes and signs it (a sample pack made with demo values is on this page). The Validation Summary Report then binds it with the test baseline and a hardware inventory for your sign-off.
What does balance software with audit trail cost per scale?
ENTERPRISE & COMPLIANCE costs 144.00 EUR a year or 599.00 EUR once per scale, the adapter board about 13.50 EUR. Usual lab software with audit trail and user management costs 600-1,800 EUR per scale and year. The routine check and all tests are free, and every scale can try ENTERPRISE for 14 days.
In detail
Pipette calibration
Labs, quality & metrologyGravimetric pipette calibration along ISO 8655-6, step by step on your lab balance: the scale takes every value, the uncertainty, the CMC, the register.
Read →Daily balance check (USP <41>)
Labs, quality & metrologyUSP <41> repeatability and minimum weight, Ph. Eur. 2.1.7, trade and HACCP checks in one minute a day.
Read →Compounding assistant
Labs, quality & metrologyThe formula step by step on your balance: every component within its tolerance, the container checked, signed records.
Read →LIMS, ELN & sensors
Labs, quality & metrologyEvery weighing to your LIMS or ELN, room values next to it, air buoyancy corrected.
Read →Also useful for you
21 CFR Part 11 audit trail
Labs, quality & metrologyWho, when, what and why in the scale - mapped to Part 11, EU GMP Annex 11 and ALCOA+, point by point, with the limits.
Read →QA guide: validation (IQ/OQ/PQ)
Labs, quality & metrologyIntroducing it in a regulated lab: the QA tasks, what the app takes over, IQ / OQ / PQ, an estimate of the effort and the steps to the sign-off.
Read →Device qualification
Labs, quality & metrologyNo clock in the scale, no WORM disk? Lock the time and the storage of every device - with templates, form and a signed record.
Read →Scale calibration & tests
Labs, quality & metrologyEccentricity, linearity, repeatability and every other test of OIML R 76-1 Annex A at the scale, with checklist and final report.
Read →USP <41> minimum weight
Repeatability, minimum weight (2000 s) and accuracy of your balance from your weighings.
Read →The same app, for other work