Pipette calibration and pipette checks on your own lab balance
A pipette calibration measures the volume a pipette delivers by weighing the water it dispenses on a balance (the gravimetric method of ISO 8655-6). With UP↑SCALE, pipettes of every maker are checked between calibrations or calibrated along ISO 8655-6:2022: your lab balance on an UP↑SCALE RS-232 adapter takes every value by itself, the UP↑SCALE does the maths - Z factor, evaporation, the uncertainty of every volume - and your register knows what is due.
- Gravimetric pipette calibration along ISO 8655-6:2022
- Every value taken from your lab balance
- Z factor, evaporation, uncertainty and your CMC
- A register with check and calibration due dates
In short
UP↑SCALE is one scale app for the lab balance you already have, on an RS-232 adapter. It guides gravimetric pipette checks and calibrations along ISO 8655-6:2022: the balance gives every value, the UP↑SCALE works out the Z factor and the uncertainty, the register shows what is due - for labs and calibration services. The pipette check is PRO (from 4.43 EUR a month); the calibration is ENTERPRISE (from 13.00 EUR a month).
Pipette check or pipette calibration: two modes for two jobs
1💧 Pipette check PRO
An intermediate check between calibrations (ISO/IEC 17025, 6.4.10): one volume, a few deliveries, the systematic and the random error against the limits of the pipette - PASS or FAIL in a few minutes. It is no calibration and gives no uncertainty; it keeps confidence in a pipette until its next calibration. A multichannel pipette: channel 1, every channel or a rotating group - e.g. 3 channels per check, and the next check takes the next 3. Also with the virtual scale (APP ONLY) and a balance on a USB cable.
2⚗ Pipette calibration ENTERPRISE
A calibration along the gravimetric reference procedure of ISO 8655-6:2022: nominal, 50 % and the lower volume, 10 deliveries each, every channel, the evaporation, the environment at the start and the end, the expanded uncertainty of every volume, as found and as left - and the sealed calibration report with the signatures of the tester and a reviewer.
How to calibrate a pipette, step by step - your hands stay on the pipette
1Scan the pipette
Its own asset label (QR, Code 128, Code 39), a maker's code (GS1: GTIN + serial) or our sticker - with the camera or a USB hand scanner. The register brings the volume, the channels and the limits: the ISO 8655-2 table, the maker specification - from the makers' list in the app, with the maker's document - or your own.
2The UP↑SCALE guides every step
Set the volume, new tip, pre-wet - OK (a foot pedal works as OK; the weight is ignored meanwhile). Then aspirate and dispense: the UP↑SCALE takes every delivery itself when the balance is stable, reads the line of the balance digit by digit (also 0.001 mg), measures the evaporation and asks KEEP or REDO when a delivery is far from the expected mass. On a multichannel pipette the next channel starts by itself - no tap between the channels.
3Result, record, sticker
Mean volume, systematic and random error, PASS or FAIL - saved at once in the register with every single value. A sticker for the pipette, a status tag for a failed one, and with ENTERPRISE the sealed PDF report with your own title and accreditation text.
Not sure what an option does? Every option of the setup, every button of the run and every field of the register and the lab settings has a small ℹ️ that explains it.


Manual: pipette check, pipette calibration, which balance
Pipette calibration uncertainty and your CMC ENTERPRISE
- The budget of every volume along ISO 8655-6:2022 / ISO/TR 20461:2023: repeatability, balance (calibration, linearity, resolution), evaporation, water and air temperature, pressure, humidity, the densities and the handling of the instrument (EURAMET cg-19) - each with its contribution on the report; U with k = 2.
- U in use for a single delivery, with the operator, laboratory and process effects from your own studies.
- Your CMC table as a CSV: the reported U is never below your CMC (raised and marked); a volume outside your scope is marked, and your accreditation text is left off that line. Every upload is a version with its SHA-256.
- Decision rule of your choice: simple acceptance or a guard band with U (PASS, FAIL, INCONCLUSIVE) - named on the report.
- Deviations named, never hidden: ISO 8655-6:2022 may be claimed only when every requirement is met. The app checks the balance, your instruments, the room and the water at the start and the end, the test volumes and the 10 deliveries; before START it lists what is missing, and the report of such a run says "based on ISO 8655-6:2022 with deviations", lists them and claims no conformity.
- Validated maths: the water density (Tanaka 2001), the air density (OIML R 111), the Z factor against the published tables, the volumes, the budget and the decision rules are reference cases of the validation of the calculations - computed by the UP↑SCALE firmware. The validation pack (ENTERPRISE) has a chapter of its own for the pipettes: requirements, risks, IQ of your instruments and balance, OQ test scripts and the PQ against an external calibration (En ≤ 1) - see the sample pack (PDF, demo values).

Manual: uncertainty, CMC table
Room and water from sensors: thermometer, hygrometer, barometer
The water temperature, the room air, the humidity and the air pressure of a run can come from sensors next to the balance. Typed values work as before, and a typed value always wins.
- 📡 One click per value, or none PRO: a room sensor and a thermometer connected in the app fill the conditions of the setup; START takes the values of that moment, the end form those of the end, and the run page warns when the room air moves more than 0.5 °C (glass 1 °C) or the water is more than 0.5 °C away from the air.
- Every value with its source ENTERPRISE: the record and the report name the sensor with its register entry, certificate and correction - or the instrument a typed value was read from. The register of your sensors and instruments keeps certificates, due dates, U and corrections; a due date that has passed counts as a deviation, and the budget takes the U of an instrument when it is bigger than your lab value.
- The room log ENTERPRISE: limits for your pipette room (presets for ISO 8655 at 20 or 27 °C) with a warning, one value a minute while the app is open, the chart of a day and a report.
- Which sensors: RuuviTag (air temperature, humidity and air pressure in one), Aranet4, Xiaomi LYWSD03MMC, Nordic Thingy:52, every sensor with the Bluetooth Environmental Sensing or Health Thermometer service, ETI BlueTherm thermometers (Thermapen Blue, ThermaQ Blue), broadcasting sensors (BTHome, Govee, pvvx), thermometers, hygrometers or barometers on a USB or RS-232 cable that send their values as text, transmitters on RS-485 with Modbus RTU (e.g. Vaisala HMP60 / HMP110) and the room monitoring you already have, over an HTTP JSON address or MQTT (all ways to connect).
- Traceable with your calibrated sensor: the app records its certificate and checks the instrument requirements of ISO 8655-6:2022 (table 2) against the U you enter.
Testers wanted: the sensors of other makers are built in and should work out of the box, but they still need more testing with real devices: room sensors (RuuviTag, Aranet4, Xiaomi LYWSD03MMC, Nordic Thingy:52, sensors with the Bluetooth Environmental Sensing service), thermometers (ETI BlueTherm, Health Thermometer), broadcasting sensors (BTHome, pvvx, Govee), serial sensors on a USB or RS-232 cable, Modbus RTU transmitters on RS-485 and monitoring systems over HTTP JSON or MQTT. If you use one of them, please tell us whether everything works for you - or which problems you see. As a thank you for your help, you get a free lifetime licence! Write to us: ![]()
The names of these devices belong to their owners; UP↑SCALE is not affiliated with or endorsed by them.
Manual: sensors, register, room log, conditions of a run
Pipette calibration records: register, import and labels
- Every pipette with its history: who changed what, when and why - each entry chained to the one before with a SHA-256 check value, so a changed or removed entry shows; the next check and calibration due; quarantine and out of service. ENTERPRISE: every change also goes into the hash-chained activity log of the UP↑SCALE, and under strict audit the register changes only while it is connected.
- The makers' specifications built in: the limits of common Eppendorf, Gilson, Rainin, Thermo Scientific, Sartorius, BRAND and Socorex pipettes as their operating manuals print them, with the document. Choose the model, and the pipette takes the maker's limits and test volumes.
- Reminders and calendar: what is overdue or due soon when the adapter connects, and all due dates as a calendar file (.ics) with an alarm for Outlook, Google or Apple Calendar.
- Customers ENTERPRISE: for a calibration service - the pipettes of each customer, the customer on each report, and the register report, labels, calendar and register file per customer.
- Your codes and ours side by side: keep your own labels, print ours (QR sticker, Code 128 asset label, status tag) on your label printer, or both.
- Import of your old list: CSV or JSON from your previous system, the columns guessed from the header, the last calibration and the due date taken along, a preview before anything changes - and an import record with the SHA-256 of the file as the evidence of the transfer.
- Shared between your devices: live while they are connected to the same UP↑SCALE, otherwise by the register file - nothing of it is kept on the scale.

Manual: pipette register, makers' specifications, customers, history, import a pipette list
Dispenser and burette calibration too
- One register, one procedure: bottle-top and repeating dispensers (ISO 8655-5) and piston burettes (ISO 8655-3, manual or the motor-driven dosing unit of a titrator) are checked and calibrated with the same gravimetric procedure of ISO 8655-6:2022 - in the same modes, with the same records, CMC table and labels.
- The vessel may leave the balance: dispense into the vessel held under the outlet, put it back - the UP↑SCALE waits for it and takes the difference by itself.
- The limits of the instrument: motor-driven burettes from ISO 8655-3:2022 table 1, manual burettes and bottle-top dispensers from maker procedures (secondary sources, editable), repeating dispensers with the maker's or your own limits - the report names the source.
- Never mixed up with the balance: every title and button names the instrument - Calibration of the piston burette as found - not the calibration of your balance.

Manual: dispensers and burettes
Volumetric glassware calibration too
- Flasks, cylinders, glass pipettes and burettes: volumetric flasks, measuring cylinders, one-mark and graduated pipettes and glass burettes in the same two modes, built along ISO 4787:2021 - a receipt or intermediate check (PRO) or a calibration with its uncertainty (ENTERPRISE).
- To contain or to deliver: a flask is weighed empty and dry, filled off the balance and put back - the UP↑SCALE takes the value and asks to empty and dry it before the next fill. A pipette or burette delivers into a weighing vessel held under the tip. Up to 2 kg of water: a 1000 mL flask fits.
- No early values: a value counts only after the item or the vessel was lifted - or after MENISCUS SET when you set the meniscus on the balance. The waiting time of AS pipettes and burettes runs as a countdown.
- Against the class tolerance: class A, AS or B from the ISO tables (ISO 1042, 648, 835, 385, 4788) or the ASTM / USP tables - values from public secondary sources, editable, named on every record. The uncertainty holds the expansion of the glass and the setting of the meniscus (EURAMET cg-19).


Manual: volumetric glassware
The limits - for your validation
- Your balance decides the volumes: ISO 8655-6 asks for d 0.001 mg below 20 µL, 0.01 mg from 20 µL and 0.1 mg from 200 µL. The UP↑SCALE 420 and 710 are far too coarse: the modes run on the RS-232 adapter (DIY on the ESP32-C3 RS232 Adapter) with your lab balance, or in the app with the virtual scale (check only).
- Traceable and accredited are yours: traceability comes from your calibrated balance, thermometer, barometer and hygrometer; an accredited calibration from your ISO/IEC 17025 scope. The app calls nothing accredited or certified.
- The values of the standards: the balance and instrument requirements and the room conditions are taken from ISO 8655-6:2022 itself. The limits of ISO 8655-2:2022 come from public secondary sources (single-channel from two, the multichannel table from one, positive displacement pipettes of type D2 from two) and can be changed in the lab settings - check them against the official text. A positive displacement pipette is D1 or D2 in the register: D1 has the limits of air displacement pipettes, D2 its own.
- Your uncertainty inputs: the standard uncertainties of your instruments and the operator / laboratory effects come from your certificates and studies; the defaults are examples.
- The register lives in your browsers, not on the scale: keep the register file as a backup.
UP↑SCALE gives you the procedure, the maths and the records - it makes no claim that you comply with a standard or that an assessor accepts them. All details: manual: pipettes.
Pipette calibration and checks: questions and answers
What is pipette calibration?
Pipette calibration finds out how much liquid a pipette really delivers, and how sure that value is. In the gravimetric method of ISO 8655-6:2022 the deliveries of water are weighed on a lab balance and turned into volumes with the Z factor - at the nominal volume, 50 % and the lower volume, 10 deliveries each. The result is the systematic and the random error against the limits of the pipette, with the uncertainty of every volume.
Can the room and water temperature come from a sensor?
Yes. A room sensor (air temperature, humidity, air pressure) and a thermometer in the water, connected over Bluetooth or a USB cable, fill the conditions of a pipette check or calibration; the start and end values are taken at that moment, and typed values still work and always win. With ENTERPRISE the record names every sensor with its calibration certificate and correction, and a register keeps the certificates, due dates and uncertainties of your sensors and instruments. Supported: RuuviTag, Aranet4, Xiaomi LYWSD03MMC, Nordic Thingy:52, sensors with the Bluetooth Environmental Sensing or Health Thermometer service, ETI BlueTherm, BTHome, Govee and serial sensors.
How do I calibrate a pipette step by step?
Along the gravimetric procedure of ISO 8655-6:2022: enter the water and air temperature, the air pressure and the humidity, let the UP↑SCALE measure the evaporation, then at each test volume fit a new tip, pre-wet it and dispense 10 times into the vessel on the balance. The UP↑SCALE takes every delivery from the balance when it is stable, corrects the evaporation, turns the masses into volumes with the Z factor and gives the systematic and the random error, the uncertainty and the verdict of your decision rule - channel after channel, with the environment entered again at the end.
How often should pipettes be calibrated?
As often as your quality system says: every pipette in the register has its own check interval and calibration interval, and the register shows what is due and what is overdue - with a reminder when the adapter connects and the due dates as a calendar file. Between two calibrations, the pipette check - an intermediate check along ISO/IEC 17025, 6.4.10 - keeps confidence in a pipette until its next calibration.
What are the acceptance criteria for pipette calibration?
The maximum permissible systematic and random errors of the pipette: by default from the ISO 8655-2 table for its nominal volume (taken from public secondary sources - check them against the official text), or the maker specification (the app has a list of them from the operating manuals of the makers, each with its document), your own limits or the limits table of your lab. The decision rule is yours too: simple acceptance or a guard band with the uncertainty (PASS, FAIL, INCONCLUSIVE). The report names the source of the limits and the rule.
Can we calibrate our pipettes in house?
Yes, on your own lab balance with an UP↑SCALE RS-232 adapter, when the balance is fine enough for the volumes (d 0.001 mg below 20 µL, 0.01 mg from 20 µL, 0.1 mg from 200 µL). The calibration is ENTERPRISE, the check PRO. Traceability comes from your calibrated balance, thermometer, barometer and hygrometer, listed on the report; an accredited calibration needs your own ISO/IEC 17025 scope - the app calls nothing accredited.
What is the difference between a pipette check and a pipette calibration?
A calibration relates the delivered volume to its reference with an uncertainty, along a defined procedure (ISO 8655-6 for the gravimetric method). An intermediate check between calibrations (ISO/IEC 17025, 6.4.10) is shorter - one volume, a few deliveries - and only shows that the pipette still meets its limits; it gives no uncertainty and replaces no calibration.
Which balance do I need to calibrate pipettes?
ISO 8655-6:2022 sets the resolution by the volume: 0.001 mg for pipettes below 20 µL, 0.01 mg from 20 µL to below 200 µL, 0.1 mg from 200 µL to 10 mL. The app shows for every test volume whether your balance is fine enough; a calibration does not start with a balance that is too coarse.
How many measurements does ISO 8655-6 require?
Ten deliveries per test volume, at the nominal volume, 50 % of it and the lower limit of the range (10 % of the nominal volume or the lowest settable volume), for every channel of a multichannel pipette.
How do we calibrate a multichannel pipette on a single-channel balance?
One channel after the other - aspirate with all channels, dispense one channel into the vessel. ISO 8655-6:2022 allows a single-channel balance for multichannel pipettes (with relaxed repeatability values for the balance); a multichannel balance may only be used for multichannel pipettes. Each channel counts as a pipette of its own, so a 12-channel pipette means 12 × 10 deliveries per volume; the UP↑SCALE starts the next channel by itself.
What if our room or our instruments do not meet ISO 8655-6?
You can still calibrate. The app lists every deviation it can see before the start and on the result, and the report then says "based on ISO 8655-6:2022 with deviations" and claims no conformity - as the standard asks in its clause 4.
Can US labs use it - CLIA, CAP, A2LA, NIST?
Yes: ASTM E1154 was withdrawn in 2023, and US labs and their accreditation bodies work with ISO 8655 and ISO/IEC 17025. The check and the calibration give you the records CLIA, CAP and FDA GLP / GMP ask for; the NIST traceability comes from your calibrated instruments listed on the report. For US labs.
What is the Z factor in pipette calibration?
It turns the mass of the water into its volume: Z = 1 / (density of water − density of air) × (1 − density of air / density of the weights). At 20 °C and 1013 hPa it is about 1.0029 µL/mg. The UP↑SCALE calculates it from the water and air temperature, the pressure and the humidity of each run.
Does the reported uncertainty respect our CMC?
Yes. Upload your CMC table as CSV: the reported expanded uncertainty is never smaller than the CMC of the volume, and a volume without a CMC row is marked outside the scope of your accreditation.
Can we calibrate bottle-top dispensers and piston burettes too?
Yes. The register knows the instrument of every entry: pipette, bottle-top or repeating dispenser, or piston burette (manual or motor-driven). Check and calibration use the same gravimetric procedure of ISO 8655-6:2022; the limits come from ISO 8655-3 (burettes) or ISO 8655-5 (dispensers), the vessel may leave the balance for a delivery, and the report names the instrument and the source of its limits.
Can we check volumetric glassware - flasks, cylinders, glass pipettes and burettes?
Yes, built along ISO 4787:2021: to contain (the item weighed empty, then filled to the mark) or to deliver (into a weighing vessel), up to 5 test points, against the class A, AS or B tolerance of an ISO or ASTM / USP table (values from secondary sources, editable). A receipt check is PRO, a calibration with the uncertainty ENTERPRISE. A value counts only after the item or the vessel was lifted, or after MENISCUS SET.
Can we import the pipettes of our old calibration software?
Yes: export the list as CSV or JSON, map the columns once (the app guesses them from the header), check the preview and import. The last calibration and the due dates come along, and the import record with the SHA-256 of the file documents the transfer.
Do the pipette modes work with pipettes of any maker?
Yes. The register takes every maker and model; the limits come from the ISO 8655-2 table, from the maker specification or from your own limits. For common Eppendorf, Gilson, Rainin, Thermo Scientific, Sartorius, BRAND and Socorex pipettes the maker specification is built in, as printed in the operating manual and with the document named; for others you type it from the maker's papers.
Can a calibration service keep the pipettes of its customers?
Yes, with ENTERPRISE: every pipette can belong to a customer. The register filters by customer, each report shows the customer as it was at the run, and the register report, the labels, the calendar file and the register file can be made for one customer.
Who else uses it
Laboratories & pharmacies
Labs, quality & metrologyThe compounding assistant from master formula to signed batch record, routine checks before use, a full test suite and records you can prove: users, roles, reasons, a hash-chained audit trail and sealed reports.
Read →Auditors & QA teams
Labs, quality & metrologyCheck the records of many scales in minutes instead of days: every file checks itself, the reviews and signatures are in the records, and the documents for the binder come out of the app.
Read →Calculation validation (IQ/OQ)
Labs, quality & metrologyReference cases worked out by hand from the standards, computed by the scale firmware, with a sealed record.
Read →Lab & pharmacy: more pages
Daily balance check (USP <41>)
Labs, quality & metrologyUSP <41> repeatability and minimum weight, Ph. Eur. 2.1.7, trade and HACCP checks in one minute a day.
Read →Compounding assistant
Labs, quality & metrologyThe formula step by step on your balance: every component within its tolerance, the container checked, signed records.
Read →LIMS, ELN & sensors
Labs, quality & metrologyEvery weighing to your LIMS or ELN, room values next to it, air buoyancy corrected.
Read →The same app, for other work
Every function is in the same app - at home, in business and in the lab. All functions at a glance.