UP↑SCALE › LABS, QUALITY & METROLOGY › LABORATORIES & PHARMACIES › LIMS, ELN & SENSORS

Balance data to your LIMS or ELN - with the room next to every weighing

Typing weights into a LIMS by hand costs time and brings errors, and the room conditions are often read off a separate display. UP↑SCALE sends the weighings and records of your balance as JSON to your own server, takes temperature, humidity and air pressure from your sensors, and adds what a lab weighing needs: the air buoyancy correction, a stability light and a minimum weight warning.

  • Weighings and records as JSON to your own LIMS or ELN
  • Room temperature, humidity and pressure from your sensors
  • Air buoyancy correction: the true mass next to the reading
  • Stability light and minimum weight warning (USP <41>)

In short

UP↑SCALE is one scale app for the balance you already have. It sends the weighings and records of your balance as JSON to your own LIMS, ELN or webhook (no third-party cloud), takes the room conditions from your sensors and shows the true mass corrected for air buoyancy. For laboratories and pharmacies. The live weight, tracking and sensor values are PRO (from 4.43 EUR a month); records, the room log, air buoyancy, stability light and minimum weight are ENTERPRISE (from 13.00 EUR a month).

LIMS / ELN forwarding: every event to your own server PROENTERPRISE

The app sends what happens at the scale straight to a server of your lab - your LIMS, your ELN, a small archive server in your network or a webhook - as JSON, one event per POST. Nothing goes to us or to any other cloud: you give the address, and only your server gets the data. Settings > 🔗 LIMS / ELN FORWARDING.

  • The app forwards, not the scale: it sends while the app is open and connected on that device. Switch it on in one app only - e.g. on the lab computer next to the balance. The settings (address, token, events) are kept in that browser.
  • Nothing of the activity log is lost: the scale keeps its entries, and the next time the app is connected it fetches the new lines and forwards each one once.
  • Every event has a fixed id: if one comes twice (after a lost answer), your server simply drops the second one.
  • The app never waits for your server: a POST without an answer is given up after 8 seconds and sent again later, in the right order; up to 1000 events wait in the browser, also over a reload. A yellow line warns when the queue fills up or your server was not reachable for an hour.

What is sent - one checkbox for each kind of event

EventWhat it holdsEdition
⚖ Live weightwhat the big weight shows, with the mode, the stability state and the serial line of the scale as plain text - when it settles or every 1, 5 or 60 secondsPRO
📈 Trackingstart, end and every alarm of a tracking run - and, if you want, every pointPRO
📝 Weighing logevery ∑ and the lines of the programs (recipes, solutions ...)ENTERPRISE
⚕ Finished programsevery compounding batch record, solution, recipe run and pipette check or calibration - also as the report file sealed by the scaleENTERPRISE
📜 Activity logevery line with sequence number, time, user, text and the chain hash - your server can check the chain itselfENTERPRISE
🔏 Sealed reportsevery seal and signature with the SHA-256 of the file - and, if you want, the file itselfENTERPRISE
🚦 Status for useevery routine check, the release state of the scale, a removed warning and every weight recorded below the minimum weightENTERPRISE
☑ Validation runsevery run of the validation of the calculations (IQ/OQ) with every caseENTERPRISE
📡 Room logone mean value a minute, every crossing of a room limit, every sensor that stops or comes backENTERPRISE
💶 📦 Sales and stockevery sale and every stock change the scale hands to the appsENTERPRISE

With a sensor connected, every event also carries the room air, humidity, air pressure and liquid of now, each with its source; with the air buoyancy correction on, a weighing also carries the true mass next to the reading.

What your server needs

  • https - a certificate of your own lab (internal CA) is fine
  • CORS headers that allow the app, and for an address in your local network the private-network header too - the manual shows them
  • an answer with a 2xx status - anything else counts as not delivered and is sent again
  • 📡 TEST sends a test event and shows the answer; the status line shows how many were sent, how many wait and the last error

The manual has a complete receiver in a few lines of PHP that writes every event as one line into a file. A receiver without CORS (some hook services and chat webhooks) works too: the app then sends the JSON as plain text with the token in the address - but it sees no answer, so nothing is sent again. For records that must arrive, use your own server with the CORS headers.

Room sensors, thermometers and lab instruments

1Your sensors next to the scale PRO

Thermometers, hygrometers and barometers of other makers connect to the app from the same browser - the UP↑SCALE stays connected. Their values fill the fields of the lab modes: pipettes and glassware, the air buoyancy correction, the batch and solution records (the room at the start and the end), the routine check, the tests, the density mode, the weighing log and the LIMS events. A value you type always wins, and every mode works without a sensor.

WayFor
Bluetoothroom sensors and thermometers with the standard Environmental Sensing or Health Thermometer service, and known models of other makers
Broadcastsensors that only send in their advertising - a coin cell lasts long (Chrome or Edge with a test switch)
USB / RS-232 cablea thermometer, hygrometer or barometer that sends lines of text (Chrome or Edge on a computer)
Modbus RTUtransmitters on RS-485 through a USB-RS485 adapter, with a preset or the register map of the maker
HTTP JSONan address in your network that answers with JSON - e.g. a small bridge in front of your monitoring system
MQTTthe topics of a broker of your lab over secure WebSockets

A value counts for 5 minutes (a liquid: 30 seconds), then as none - no old value lands in a record. Every way to connect →

2The register of sensors and instruments ENTERPRISE

For each device: name or asset number, serial number, calibration certificate with its date and due date, and for each value the expanded uncertainty U (k = 2) and the correction from the certificate - reading + correction = the value used. Instruments without Bluetooth go in too (a glass thermometer, a hand-held barometer): pick one next to a typed value and the record names it. A due date that has passed shows ⚠. Only an ADMIN or a QM changes the register; every change keeps who, when, the old and the new value, and with an ENTERPRISE UP↑SCALE connected it is an entry in its activity log. An entry no longer used is retired, never deleted.

3Room limits and the room log ENTERPRISE

The values of now are PRO. ENTERPRISE adds limits for air temperature, humidity and the change of the air within an hour (presets for pipette labs after ISO 8655 at 20 or 27 °C) with a warning when the room leaves them, and the room log: one mean value a minute, with the chart of a day, CSV and a report. A sensor that stops sending leaves a gap, and the log notes since when. The room log, its limits and its gaps can go to your LIMS too.

What a lab weighing needs

4Air buoyancy correction: the true mass next to the reading ENTERPRISE

A balance is adjusted with steel weights (8.0 g/cm³), so it shows the conventional mass. A sample of a lower density pushes away more air and shows a bit less than its true mass: water about +0.105 %, ethanol about +0.137 %, a powder of 1.5 g/cm³ about +0.065 %. Switched on, the UP↑SCALE calculates true mass = reading × (1 - ρ air / 8.0) / (1 - ρ air / ρ sample) for every THING with a density. Without a density nothing is corrected - never a guess. The reading itself is never changed: the true mass is shown and recorded next to it.

  • Air density: 0.00120 g/cm³, your own value, or worked out from temperature, pressure and humidity with the formula of OIML R 111 - also filled from your room sensors, and kept up to date by them if you switch it on
  • Where it is used: the weighing page, the solution mode and recipes (the goals are true masses, the scale judges green / red with the correction), the density mode, the weighing log, the reports and the LIMS events
  • Where it is not: calibration, the tests and the routine check, the minimum weight, check-weighing, sorting, counting, sales and the stock - there the conventional mass is the rule
  • Kept on the scale for every device; with users only an ADMIN changes it, and every change is an entry of the activity log with the old and the new value

5Stability light: moving, settling, settled ENTERPRISE

STABLE only says that the shown weight stands still - draft or vibration can still move it inside one digit. With the stability light on (in the basic settings, off by default) a line below the weight shows MOVING (red), SETTLING (yellow, pulsing, with the spread in d) and SETTLED (green: the spread stayed at 0.5 d or less for 1 second). The scale decides this itself, so every connected app shows the same. Labels, the inventory check and taking a weight into a field then wait for SETTLED and save by themselves - or you press SAVE ANYWAY, and the activity log notes it with the weight and the user. The live weight to your LIMS is then sent when it is SETTLED.

6Minimum weight warning (USP <41>) ENTERPRISE

Below the minimum weight of a balance the relative error is too big for analytical work. Type it in once from the calibration certificate or the qualification of your balance - the scale keeps it for every device (an RS-232 adapter one per scale profile). Below it, a ∑, a booking and a label ask first and say "BELOW THE MINIMUM WEIGHT"; recorded anyway, the activity log notes it with the weight, and the LIMS events mark it. Without a value nothing is checked. The routine check with the USP or Ph. Eur. profile shows the minimum weight it measures as a help - the value you type in is yours. Free USP <41> minimum weight calculator →

Is the place of your balance steady?

  • The environment test (in the settings) measures for 3 minutes how much the readings swing and drift on your table, says what kind of unrest it is and recommends the fastest speed setting that keeps the display steady - nothing changes without your click.
  • The environment filter AUTO repeats it in the background while the scale stands still and adapts the averaging - your saved settings are never changed.
  • It is a recommendation for this place and these minutes, not a measurement result.

The limits - honestly

  • The app forwards, not the scale: while the app is closed or the device sleeps, live weights, weighings and tracking events of that time are not sent. Only the activity log catches up by itself.
  • Forwarding is no archive of its own: it hands the events to your server; keeping them unchanged is the job of your own append-only storage.
  • The room log runs only while the app is open and a room sensor is connected - it is no continuous monitoring of the room.
  • Traceable values come from the calibration certificate of your sensor, not from the app. The sensor drivers are written from the published protocols - tell us how it works with yours.
  • The air buoyancy correction is a calculation along OIML R 111 with the density you give - only as good as that density and the air values.
  • Editions: live weight, tracking and the sensor values are PRO; everything else on this page is ENTERPRISE & COMPLIANCE (14 days free to try).

For laboratories & pharmacies → · the compounding assistant → · the audit trail →

LIMS forwarding, room sensors and lab weighing: questions and answers

Can the balance send its results to our LIMS or ELN?

Yes. The app sends events as JSON, one per POST, to a server in your own network or a webhook: the live weight and tracking with PRO, and with ENTERPRISE the weighing log, finished batches and reports, the activity log, sealed files, the release state of the balance, validation runs and the room log. No third-party cloud.

Does the scale need a network connection?

No. The scale itself sends nothing to the network - the app on the phone or computer next to it forwards. It sends while it is open and connected; the activity log catches up by itself at the next connection.

Which LIMS does it work with?

With any server that takes a JSON POST over https and answers with a 2xx status: your LIMS or ELN, a small archive server, or a webhook service. The manual has the CORS headers and a complete receiver in PHP.

What happens when our server is down?

The app never waits for it: a failed event is sent again later, in the right order, and up to 1000 events wait in the browser, also over a reload. A yellow line warns when the queue fills up or the server was not reachable for an hour.

Can the app read our room sensors or monitoring system?

Yes, next to the scale: Bluetooth room sensors and thermometers, sensors that broadcast, sensors on a USB or RS-232 cable, transmitters on RS-485 with Modbus RTU, an HTTP address that answers with JSON and an MQTT broker over WebSockets. A typed value always wins.

Is the room log a continuous room monitoring?

No. It keeps one mean value a minute while the app is open and a room sensor is connected, with limits and warnings (ENTERPRISE). A sensor that stops sending leaves a gap, and the log notes since when.

Does it correct for air buoyancy?

Yes, with ENTERPRISE: for every THING with a density the UP↑SCALE shows the true mass next to the reading - water about +0.105 %, ethanol about +0.137 %. The air density is 0.0012 g/cm³, typed in, or worked out from temperature, pressure and humidity with the formula of OIML R 111. The reading is never changed.

What is the stability light?

A line below the weight that shows MOVING, SETTLING and SETTLED - the scale decides it from how much the weight still moves. Labels and records wait for SETTLED and save by themselves; SAVE ANYWAY is noted in the activity log. ENTERPRISE, off by default.

How does the minimum weight warning work?

Type in the minimum weight of your balance once, from its calibration certificate or qualification. Below it, a sum, a booking or a label asks first; recorded anyway, the activity log notes it and the LIMS events mark it. ENTERPRISE; without a value nothing is checked.

Also useful for you

Who else uses it

Lab & pharmacy: more pages

The same app, for other work

Every function is in the same app - at home, in business and in the lab. All functions at a glance.

Last updated · by Johann Anderson, FARM 23 SL

READY TO UP↑SCALE YOUR SCALE?

Start with the free version - the board costs under 15 EUR and you may never need more. If you do, unlock PRO from 4.43 EUR a month, 46.90 EUR a year or once for 119.90 EUR incl. VAT - or ENTERPRISE & COMPLIANCE from 13.00 EUR a month (once: 599.00 EUR). The lifetime licences are once and forever, no subscription needed; no advertisements, everything works offline, updates stay free.